<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">radhyd</journal-id><journal-title-group><journal-title xml:lang="ru">Радиационная гигиена</journal-title><trans-title-group xml:lang="en"><trans-title>Radiatsionnaya Gygiena = Radiation Hygiene</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-426X</issn><issn pub-type="epub">2409-9082</issn><publisher><publisher-name>NIIRG</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21514/1998-426X-2024-17-2-38-45</article-id><article-id custom-type="elpub" pub-id-type="custom">radhyd-1037</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Научные статьи</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Scientific articles</subject></subj-group></article-categories><title-group><article-title>Возможность  использования  дозиметра  ДКС-АТ1123  для  радиационного  контроля  медицинских  ускорителей  электронов  с  энергией  более  10  МэВ</article-title><trans-title-group xml:lang="en"><trans-title>The  possibility  of  using  the  DKS-AT1123  dosimeter  for  radiation  monitoring  of  medical  electron  accelerators  with  the  energy  of  more  than  10  MeV</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Барковский</surname><given-names>А. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Barkovsky</surname><given-names>A. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Барковский  Анатолий  Николаевич  –  руководитель Федерального радиологического  центра,  главный научный сотрудник</p><p> 197101, Санкт-Петербург, ул. Мира, д. 8</p></bio><bio xml:lang="en"><p>Anatoly N. Barkovsky – Head of the Federal Radiological Center</p><p>Mira Str., 8, Saint-Petersburg, 197101</p></bio><email xlink:type="simple">anbarkovski@yandex.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Огородников</surname><given-names>С. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Ogorodnikov</surname><given-names>S. A.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Огородников  Сергей  Анатольевич  –  генеральный директор</p><p>Санкт-Петербург</p></bio><bio xml:lang="en"><p>Sergey A. Ogorodnikov – General Director</p><p>Saint-Petersburg</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Санкт-Петербургский научно-исследовательский институт имени профессора П.В.Рамзаева, Федеральной службы по надзору в сфере защиты прав потребителей и благополучия человека</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Saint-Petersburg  Research   Institute   of   Radiation  Hygiene  after   Professor   P.V.   Ramzaev,  Federal  Service  for  Surveillance of Consumer Rights Protection and  Human Wellbeing</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Общество с ограниченной ответственностью «Лаборатория Скантроник»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Limited liability company  «Laboratory Scantronic»</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>04</day><month>07</month><year>2024</year></pub-date><volume>17</volume><issue>2</issue><fpage>38</fpage><lpage>45</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Барковский А.Н., Огородников С.А., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Барковский А.Н., Огородников С.А.</copyright-holder><copyright-holder xml:lang="en">Barkovsky A.N., Ogorodnikov S.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.radhyg.ru/jour/article/view/1037">https://www.radhyg.ru/jour/article/view/1037</self-uri><abstract><p>В  Российской  Федерации  наблюдается  постоянный  рост  количества  используемых  радиационных медицинских установок с ускорителями электронов. За последние 4 года их количество возросло в 2,5 раза. Данные установки содержат импульсные ускорители электронов, генерирующие импульсное тормозное излучение с максимальной энергией от 6 до 21 МэВ. В государственном реестре средств измерений Российской Федерации в настоящее время отсутствуют приборы, предназначенные для дозиметрии импульсного фотонного излучения с энергией более 10 МэВ. Наиболее широко используется для  проведения  радиационного  контроля  импульсных  ускорителей  электронов  дозиметр  рентгеновского и гамма-излучения ДКС-АТ1123, предназначенный для дозиметрии импульсного тормозного из -лучения с энергией до 10 МэВ. Цель настоящей работы – оценить возможность использования данного прибора для дозиметрии импульсного тормозного излучения с максимальной энергией до 20  МэВ. Авторами были проведены расчеты энергетических спектров тормозного излучения для точечного источника с максимальной энергией 20 МэВ за плоскими бетонными экранами толщиной 1  м, 2  м и 3 м методом Монте-Карло с использованием расчетной программы GEANT4. Проведена экстраполяция энергетической зависимости эффективности регистрации дозиметра ДКС-АТ1123 в область энергий  10–50  МэВ  в  керма-приближении,  т.е.  без  учета  переноса  энергии  вторичными  электронами. Предполагалось,  что  она  соответствует  энергетической  зависимости  полного  массового  коэффициента ослабления для поглощенной энергии гамма-квантов в воде. С использованием конверсионных коэффициентов перевода флюенса моноэнергетических фотонов в мощность эффективной дозы для передне-задней геометрии облучения были получены реальные значения мощности дозы, а с использованием энергетической зависимости показаний дозиметра – прогнозируемые результаты измерения дозиметром ДКС-АТ1123 единичной мощности дозы за бетонной защитой толщиной 1, 2 и 3 м. Показано, что максимальное ожидаемое занижение результатов измерений не превысит 40% и практически не зависит от толщины бетонной защиты в  диапазоне толщин от 1 до 3 м. Для учета данного занижения необходимо использовать значение дополнительной погрешности измерений за счет энергетической зависимости чувствительности данного прибора для энергии фотонного излучения более 10 МэВ, равное 70%. Это позволяет использовать результаты измерений, полученные с использованием данного дозиметра, для адекватной характеристики состояния радиационной обстановки при эксплуатации импульсных ускорителей электронов с максимальной энергией до 20 МэВ. Для компенсации данного занижения возможно использование поправочного коэффициента к результатам измерений, равного для рассмотренных условий 1,63 ±0,04. Предложенный подход может быть использован для создания методики радиационного контроля медицинских ускорителей электронов с энергией до 20  МэВ с использованием данного дозиметра, при наличии поправочных коэффициентов для встречающихся на практике конфигураций радиационной защиты и энергий излучения.</p></abstract><trans-abstract xml:lang="en"><p>In  the  Russian  Federation,  there  is  a  constant  increase  in  the  number  of  radiation  medical  installations  with electron accelerators. Over the past 4 years, their number has increased 2.5 times. These installations contain pulsed electron accelerators that generate pulsed bremsstrahlung radiation with a maximum energy from 6 to 21 MeV. Currently, there are no devices designed for dosimetry of the pulsed photon radiation with energy of more than 10 MeV in the state register of measuring instruments of the Russian Federation. The most widely used radiation monitoring device for pulsed electron accelerators is the DKS-AT1123 X-ray and gamma radiation dosimeter designed for dosimetry of pulsed bremsstrahlung radiation with an energy of up to 10 MeV. The purpose of this work is to evaluate the possibility of using this device for dosimetry of pulsed bremsstrahlung radiation with a maximum energy of up to 20 MeV. The authors calculated the energy spectra of bremsstrahlung radiation for a point source with a maximum energy of 20 MeV behind flat concrete screens with a thickness of 1 m, 2 m and 3 m by the Monte Carlo method using the GEANT4 calculation program. The energy dependence of the registration efficiency of the DKS-AT1123 dosimeter was extrapolated to the energy range of 10–50 MeV in the kerma-approximation without taking into account the energy transfer by secondary electrons. It was assumed that it corresponds to the energy dependence of the total mass attenuation coefficient for the absorbed energy of gamma quanta in water. Using conversion coefficients for converting the fluence of monoenergetic photons into the effective dose rate at an anterior-posterior radiation incidence on the human body, real dose rates were calculated, and using the energy dependence of the dosimeter readings, the predicted results of measuring the unit dose rate with the DKS-AT1123 dosimeter behind a concrete protection with a thickness of 1, 2 and 3 m were obtained. It is shown that the maximum expected underestimation of the measurement results will not exceed 40% and practically does not depend on the thickness of the concrete shield in the thickness range from 1 to 3 m. To account for this underestimation, it is necessary to use the value of additional measurement error due to the energy dependence of the sensitivity of this device for the photon radiation energy of more than 10 MeV, equal to 70%. This makes it possible to use the measurement results obtained using this dosimeter to adequately characterize the state of radiation safety during operation of pulsed electron accelerators with a maximum energy of up to 20 MeV. It is possible to use a correction factor to the measurement results equal to 1.63 ±0.04 to compensate for this underestimation. The proposed approach can be used to create a methodology for using this dosimeter for radiation monitoring of medical electron accelerators with the energy of up to 20 MeV, if there are correction factors for radiation protection configurations and radiation energies encountered in practice.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>радиационные медицинские установки с ускорителями электронов</kwd><kwd>импульсное  тормозное излучение</kwd><kwd>дозиметрия импульсного тормозного излучения с максимальной энергией 20 МэВ</kwd></kwd-group><kwd-group xml:lang="en"><kwd>radiation medical installations with electron accelerators</kwd><kwd>pulsed bremsstrahlung radiation</kwd><kwd>dosimetry of pulsed bremsstrahlung radiation with a maximum energy of 20 MeV</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Шевкун И.Г., Степанов В.С., Романович И.К. и др. Результаты радиационно-гигиенической паспортизации в субъектах Российской Федерации за 2017 год. Радиационно-гигиенический паспорт Российской Федерации. М.: Федеральная служба по надзору в сфере защиты прав потребителей и благополучия человека, 2018. 128 с.</mixed-citation><mixed-citation xml:lang="en">Shevkun IG, Stepanov VS, Romanovich IK, Barkovsky AN, Baryshkov NK, Bratilova AA, et al. Results of radiation-hygienic passportization in the subjects of the Russian Federation for 2017 (Radiation-hygienic passport of the Russian Federation). Moscow: Federal Service for Supervision of Consumer Rights Protection and Human Well-Being; 2018. 128 p. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Шевкун И.Г., Степанов В.С., Романович И.К. и др. Результаты радиационно-гигиенической паспортизации в субъектах Российской Федерации за 2021 год (Радиационно-гигиенический паспорт Российской Федерации). М.: Федеральная служба по надзору в сфере защиты прав потребителей и благополучия человека, 2022. 125 с.</mixed-citation><mixed-citation xml:lang="en">Shevkun IG, Stepanov VS, Romanovich IK, Barkovsky AN, Baryshkov NK, Bratilova AA, et al. Results of radiation-hygienic passportization in the subjects of the Russian Federation for 2021 (Radiation-hygienic passport of the Russian Federation). Moscow: Federal Service for Supervision of Consumer Rights Protection and Human Well-Being; 2022. 125 p. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Мартынюк Ю.Н. Государственный реестр средств изме рений. Часть 2. Дозиметры общего назначения, импульсные и специальные // АНРИ. 2020. № 4 (103). С. 3-13.</mixed-citation><mixed-citation xml:lang="en">Martinuk U.N. The State Register of Measuring Instruments. Part 2. General-purpose, pulse and special dosimeters. ANRI = ANRI. 2020;4(103):3-13. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Описание типа средства измерений. Дозиметры рентге новского и гамма-излучения ДКС-АТ1121, ДКС-АТ1123. Приложение к свидетельству № 75466 об утверждении типа средств измерений.</mixed-citation><mixed-citation xml:lang="en">Description of the type of measuring instrument. X-ray and gamma radiation dosimeters DKS-AT1121, DKS-AT1123. Appendix to Certificate No. 75466 on type approval of measuring instruments. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Описание типа средства измерений. Дозиметры RAM ION . Приложение к свидетельству № 64658 об утверждении типа средств измерений.</mixed-citation><mixed-citation xml:lang="en">Description of the type of measuring instrument. RUMION dosimeters. Appendix to Certificate No. 64658 on type approval of measuring instruments. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Описание типа средства измерений. Дозиметры-радиометры ДКС-96. Приложение к свидетельству № 43717 об утверждении типа средств измерений.</mixed-citation><mixed-citation xml:lang="en">Description of the type of measuring instrument. Dosimeters-radiometers DKS-96. Appendix to Certificate No. 43717 on type approval of measuring instruments. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Титов Н.В. Возможность применения дозиметров со счет-чиком Гейгера-Мюллера для дозиметрии импульсного излучения // Радиационная гигиена. 2019. Т. 12, № 2. С. 76-80.</mixed-citation><mixed-citation xml:lang="en">Titov NV. The possibility of using dosimeters with a Geiger-Muller counter for dosimetry of pulsed radiation. Radiatsionnaya Gygiena = Radiation hygiene. 2019;12(2): 76-80. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Дозиметры рентгеновского и гамма-излучения ДКС-АТ1121, ДКС-АТ1121А, ДКС-АТ1123, ДКС-АТ1123А. Руководство по эксплуатации. 69 с.</mixed-citation><mixed-citation xml:lang="en">X-ray and gamma radiation dosimeters DKS-AT1121, DKS-AT1121A, DKS-AT1123, DKS-AT1123A. User Manual. 69 p. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Мордасов Н.Г., Иващенко Д.М., Членов А.М., Астахов А.А. Моделирование методов экспрессного определения энергетического спектра тормозного излучения ускорителей электронов // Журнал технической физики. 2004. Т. 74, вып. 9. С. 108-115.</mixed-citation><mixed-citation xml:lang="en">Mordasov NG, Ivaschenko DM, Chlenov AM, Astakhov AA. Modeling of methods for express determination of the energy spectrum of the bremsstrahlung radiation of electron accelerators. Zhurnal tekhnicheskoy fiziki = Journal of Technical Physics. 2004;74(9): 108-115. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Абибуллаев Н.А., Бегимкулов Х.Х., Салихбаев У.С. Энергентические спектры и угловое распределение тормозного излучения, испускаемого из толстой вольфрамовой мишени электронами с энергией 11,8 МэВ // Атомная энергия. 2002. Т. 92, вып. 3. С. 247-249.</mixed-citation><mixed-citation xml:lang="en">Abibullaev NA, Begimkulov HH, Salihbaev US. Energy spectra and angular distribution of the bremsstrahlung radiation emitted from a thick tungsten target by electrons with an energy of 11.8 MeV. Atomnaya energiya = Atomic Energy. 2002;92(3): 247-249. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Нурлыбаев К., Мартынюк Ю.Н., Каракаш А.И. и др. Радиационная безопасность в лучевой терапии с использованием ускорителей электронов // АНРИ. 2014. № 1. С. 15-21 с.</mixed-citation><mixed-citation xml:lang="en">Nurlybaev K, Martinyuk UN, Karakash AI, Sinnikov LL, Lykova EN, Galjautdinova ZZ, et al. Radiation safety in radiation therapy using electron accelerators. ANRI = ANRI. 2014;1: 15-21. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Абибуллаев Н.А., Салихбаев У.С. Энергентические спектры и угловые распределения тормозного излучения, испускаемого электронами с энергией 20 МэВ из толстой вольфрамовой мишени // Известия РАН. 2000. Т. 64, № 1. С. 152-160.</mixed-citation><mixed-citation xml:lang="en">Abibullaev NA, Salikhbaev US. Energy spectra and angular distributions of the bremsstrahlung radiation emitted by electrons with an energy of 20 MeV from a thick tungsten target. Izvestiya RAN = Izvestiya RAS . 2000;64(1): 152-160. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Сахаров В.К. Спектры тормозного излучения и фотоней тронов из вольфрамовой мишени ускорителя электронов энергией 5 – 90 МэВ // Атомная энергия. 2016. Т. 120, вып . 4. С. 228-231.</mixed-citation><mixed-citation xml:lang="en">Sakharov VK. Spectra of bremsstrahlung radiation and photoneutrons from a tungsten target of an electron accelerator with an energy of 5 – 90 MeV. Atomnaya energiya = Atomic Energy. 2016;120(4): 228-231. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Allison J., Amako K., Apostolakis J. et al. Geant4 developments and applications // IEEE Transactions on Nuclear Science. 2006. Vol. 53, No. 1. P. 270-278.</mixed-citation><mixed-citation xml:lang="en">Allison J, Amako K, Apostolakis J, Araújo H, Dubois PA, Asaiet M, et al. Geant4 developments and applications. IEEE Transactions on Nuclear Science. 2006;53(1): 270-278.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Сторм Э., Исраэль Х. Сечения взаимодействия гамма-излучения (для энергий 0,001–100 МэВ и элементов с 1 по 100) Справочник. Перевод с английского В . А . Климанова , Е . Д . Чистова. М . : Атомиздат, 1973. 256 с .</mixed-citation><mixed-citation xml:lang="en">Storm E, Israel H. Cross sections of the interaction of gamma radiation (for energies 0.001 – 100 MeV and elements from 1 to 100) Handbook. Translated from English by Candidates of Technical Sciences VA Klimanov, ED Chistova. Moscow: Atomizdat; 1973. 256 p. (In Russian).</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">ICRP Publication 116. Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures // Annals of the ICRP. 2010. Vol. 40, No 2-5. P. 1-257. DOI: 10.1016/j.icrp.2011.10.001.</mixed-citation><mixed-citation xml:lang="en">ICRP Publication 116. Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures. Annals of the ICRP . 2010;40(2-5): 1-257. DOI: 10.1016/j.icrp.2011.10.001.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
