<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">radhyd</journal-id><journal-title-group><journal-title xml:lang="ru">Радиационная гигиена</journal-title><trans-title-group xml:lang="en"><trans-title>Radiatsionnaya Gygiena = Radiation Hygiene</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-426X</issn><issn pub-type="epub">2409-9082</issn><publisher><publisher-name>NIIRG</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21514/1998-426X-2024-17-2-46-52</article-id><article-id custom-type="elpub" pub-id-type="custom">radhyd-1038</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Научные статьи</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Scientific articles</subject></subj-group></article-categories><title-group><article-title>О  необходимой  толщине  стационарной  защиты  в  рентгеновских  стоматологических  кабинетах</article-title><trans-title-group xml:lang="en"><trans-title>About the necessary thickness of stationary shield in X-ray dental rooms</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Голиков</surname><given-names>В. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Golikov</surname><given-names>V. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Голиков  Владислав  Юрьевич  –  старший  научный сотрудник, лаборатория радиационной гигиены медицинских организаций</p><p>197101, Санкт-Петербург, ул. Мира, д. 8</p></bio><bio xml:lang="en"><p>Vladislav Yu. Golikov – Senior Researcher of the Medical Protection Laboratory</p><p>Mira str., 8, Saint-Petersburg, 197101</p></bio><email xlink:type="simple">sg235@rambler.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Санкт-Петербургский научно-исследовательский институт радиационной гигиены имени профессора П.В.Рамзаева, Федеральная служба по надзору в сфере защиты прав потребителей и благополучия человека</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Saint-Petersburg Research  Institute  of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and  Human Wellbeing</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2024</year></pub-date><pub-date pub-type="epub"><day>04</day><month>07</month><year>2024</year></pub-date><volume>17</volume><issue>2</issue><fpage>46</fpage><lpage>52</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Голиков В.Ю., 2024</copyright-statement><copyright-year>2024</copyright-year><copyright-holder xml:lang="ru">Голиков В.Ю.</copyright-holder><copyright-holder xml:lang="en">Golikov V.Y.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.radhyg.ru/jour/article/view/1038">https://www.radhyg.ru/jour/article/view/1038</self-uri><abstract><p>В статье на основе анализа научной информации в отношении параметров проведения и характеристик полей излучения для 3 дентальных рентгенологических процедур (внутриротовые снимки, обзорные  снимки  на  ортопантомографах  и  конусно-лучевая  компьютерная  томография)  кратко описана методология и приведены примеры расчетов необходимой толщины стационарной защиты кабинетов с разным рентгеновским оборудованием. Показано, что в большинстве случаев в кабинетах, где выполняются внутриротовые снимки и обзорные снимки на ортопантомографах, обычные внутрикомнатные  перегородки  из  гипсокартона  толщиной  20  мм  обеспечивают  необходимую  за щиту для соблюдения в соседнем помещении предела дозы для населения. Для кабинетов, где проводятся  дентальные  исследования  с  применением  компьютерных  томографов,  необходима  дополнительная защита из свинца толщиной до 1,5 мм в зависимости от условий проведения и категории защищаемых лиц в соседнем помещении.</p></abstract><trans-abstract xml:lang="en"><p>In the paper, based on the analysis of scientific information regarding the parameters and characteris-tics of radiation fields for three dental X-ray procedures (intraoral radiographs, panoramic radiographs on orthopantomographs and computed tomography), the required thickness of stationary shields for rooms with different X-ray equipment is calculated. It has been shown that in most cases, in rooms where intraoral and panoramic radiographs are taken, conventional 20 mm thick plasterboard interior room partitions provide the necessary protection to comply with the dose limit for the population in the adjacent room. For the rooms where dental examinations are carried out using computed tomographs additional lead shield up to 1.5 mm thick is required depending on the conditions and the category of protected persons in the adjacent room.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>медицинские исследования</kwd><kwd>рентгеновский стоматологический кабинет</kwd><kwd>стационарная защита</kwd><kwd>коэффициент рассеяния</kwd><kwd>прямое излучение</kwd><kwd>рассеянное излучение</kwd></kwd-group><kwd-group xml:lang="en"><kwd>medical  investigations</kwd><kwd>X-ray  dental  room</kwd><kwd>stationary  shield</kwd><kwd>scatter   coefficient</kwd><kwd>direct  radiation</kwd><kwd>scatter radiation</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Работа  была  выполнена  в  рамках  инициативной  НИР  «Научное обоснование изменений в расчетах стационарной защиты в рентгеновских кабинетах»</funding-statement><funding-statement xml:lang="en">The  work  was  performed  within  the  framework  of  the  initiative research project “Scientific justification for changes  in the calculations of stationary shielding in X-ray rooms”.</funding-statement></funding-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and Effects of Ionizing Radiation. UNSCEAR 2008 Report to the General Assembly with Scientific Annexes. Volume II. (New York, UN: Scientific Annexes C, D and E), 2011.</mixed-citation><mixed-citation xml:lang="en">United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and Effects of Ionizing Radiation. UNSCEAR 2008 Report to the General Assembly with Scientific Annexes. Volume II, (New York, UN: Scientific Annexes C, D and E); 2011.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Голиков В.Ю. Критический анализ существующего подхода к расчету стационарной защиты в рентгеновских кабинетах // Радиационная гигиена. 2023. Т. 16, № 3. С. 13–21. DOI: 10.21514/1998-426X-2023-16-3-13-21.</mixed-citation><mixed-citation xml:lang="en">Golikov VYu. Critical analysis of the existing approach to the cal-culation of radiation shielding in X-ray rooms. Radiatsionnaya Gygiena = Radiation Hygiene . 2023;16(3): 13-21. (In Russian). DOI: 10.21514/1998-426X-2023-16-3-13-21.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Archer B.R., Thornby J.I., Bushong S.C. Diagnostic X-Ray Shielding Design Based on an Empirical Model of Photon Attenuation // Health Physics. 1983. Vol. 44. P. 507-517.</mixed-citation><mixed-citation xml:lang="en">Archer B.R., Thornby J.I., Bushong S.C. Diagnostic X-Ray Shielding Design Based on an Empirical Model of Photon Attenuation // Health Physics. 1983. Vol. 44. P. 507-517.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">NCRP (National Council on Radiation Protection and Measurements). Radiation Protection in Dentistry. NCRP Report No. 145. NCRP, 2004.</mixed-citation><mixed-citation xml:lang="en">NCRP (National Council on Radiation Protection and Measurements). Radiation Protection in Dentistry. NCRP Report No. 145. NCRP, 2004.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Colin J. Martin. Radiation shielding for diagnostic radiology // Radiation Protection Dosimetry. 2015. Vol. 165(1–4). P. 376–381. doi:10.1093/rpd/ncv040.</mixed-citation><mixed-citation xml:lang="en">Colin J. Martin. Radiation shielding for diagnostic radiology // Radiation Protection Dosimetry. 2015. Vol. 165(1–4). P. 376–381. doi:10.1093/rpd/ncv040.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">European Commission. European guidelines on Radiation Protection in dental radiology. The safe use of radiographs in dental practice. Radiation Protection 136. European Communities, 2004.</mixed-citation><mixed-citation xml:lang="en">European Commission. European guidelines on Radiation Protection in dental radiology. The safe use of radiographs in dental practice. Radiation Protection 136. European Communities, 2004.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Use and regulatory control of dental x-ray installations ST3.1. Radiation and Nuclaer Safety Authority, Finland, 1999.</mixed-citation><mixed-citation xml:lang="en">Use and regulatory control of dental x-ray installations ST3.1. Radiation and Nuclaer Safety Authority, Finland, 1999.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">National Radiological Protection Board. Guidance notes for dental practitioners on the safe use of x-ray equipment. NRPB dental x-ray protection services, 2001.</mixed-citation><mixed-citation xml:lang="en">National Radiological Protection Board. Guidance notes for dental practitioners on the safe use of x-ray equipment. NRPB dental x-ray protection services, 2001.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Helmrot E., Carlsson G.Alm. Measurement of radiation dose in dental radiology // Radiation Protection Dosimetry. 2005. Vol.114, No.1-3. P. 168-171.</mixed-citation><mixed-citation xml:lang="en">Helmrot E., Carlsson G.Alm. Measurement of radiation dose in dental radiology // Radiation Protection Dosimetry. 2005. Vol.114, No.1-3. P. 168-171.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Worrall M., McVey S., Suon D.G. Proposals for revised factors in intra-oral radiography shielding calculaons // Journal of Radiological Protection. 2012. Vol. 32, No 3. P. 243-249. doi: 10.1088/0952-4746/32/3/243.</mixed-citation><mixed-citation xml:lang="en">Worrall M., McVey S., Suon D.G. Proposals for revised factors in intra-oral radiography shielding calculaons // Journal of Radiological Protection. 2012. Vol. 32, No 3. P. 243-249. doi: 10.1088/0952-4746/32/3/243.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Reid J.A., MacDonald J.C., Dekker T.A., Kuppers B.U. Radiation exposures around a panoramic dental X-ray unit // Oral Surgery, Oral Medicine, Oral Pathology. 1993. Vol. 75. P. 780-782.</mixed-citation><mixed-citation xml:lang="en">Reid J.A., MacDonald J.C., Dekker T.A., Kuppers B.U. Radiation exposures around a panoramic dental X-ray unit // Oral Surgery, Oral Medicine, Oral Pathology. 1993. Vol. 75. P. 780-782.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Williams J.R., Fipem MSc, Montgomery A. Measurement of dose in panoramic dental radiology // British Journal of Radiology. 2000. Vol. 73, P. 1002-1006.</mixed-citation><mixed-citation xml:lang="en">Williams J.R., Fipem MSc, Montgomery A. Measurement of dose in panoramic dental radiology // British Journal of Radiology. 2000. Vol. 73, P. 1002-1006.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Isoardi P., Ropolo R. Measurement of dose–width product in panoramic dental radiology // British Journal of Radiology. 2003. Vol. 76, P. 129-131.</mixed-citation><mixed-citation xml:lang="en">Isoardi P., Ropolo R. Measurement of dose–width product in panoramic dental radiology // British Journal of Radiology. 2003. Vol. 76, P. 129-131.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Holroyd J.R., Walker A. Recommendations on the design of X-ray facilities and the quality assurance of dental cone beam CT systems. HPARPD-065. Chilton: HPA, 2010.</mixed-citation><mixed-citation xml:lang="en">Holroyd J.R., Walker A. Recommendations on the design of X-ray facilities and the quality assurance of dental cone beam CT systems. HPARPD-065. Chilton: HPA, 2010.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
