<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">radhyd</journal-id><journal-title-group><journal-title xml:lang="ru">Радиационная гигиена</journal-title><trans-title-group xml:lang="en"><trans-title>Radiatsionnaya Gygiena = Radiation Hygiene</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-426X</issn><issn pub-type="epub">2409-9082</issn><publisher><publisher-name>NIIRG</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">radhyd-401</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Научные статьи</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Scientific articles</subject></subj-group></article-categories><title-group><article-title>ПРИМЕНЕНИЕ ТВЕРДОТЕЛЬНЫХ ТРЕКОВЫХ ДЕТЕКТОРОВ ДЛЯ ИЗМЕРЕНИЯ СОДЕРЖАНИЯ СВЕРХМАЛЫХ КОЛИЧЕСТВ АЛЬФА-ИЗЛУЧАТЕЛЕЙ</article-title><trans-title-group xml:lang="en"><trans-title>APPLICATION OF SOLID-STATE TRACK DETECTORS FOR MEASUREMENT OF THE LOW-LEVEL ACTIVITY OF ALPHA-EMITTERS</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Горбачев</surname><given-names>С. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Gorbachev</surname><given-names>S. G.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Научно-исследовательский институт радиационной защиты Академии технологических наук Украины</institution><country>Украина</country></aff><aff xml:lang="en"><institution>Radiation Protection Institute</institution><country>Ukraine</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2009</year></pub-date><pub-date pub-type="epub"><day>19</day><month>01</month><year>2017</year></pub-date><volume>2</volume><issue>2</issue><fpage>53</fpage><lpage>56</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Горбачев С.Г., 2016</copyright-statement><copyright-year>2016</copyright-year><copyright-holder xml:lang="ru">Горбачев С.Г.</copyright-holder><copyright-holder xml:lang="en">Gorbachev S.G.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.radhyg.ru/jour/article/view/401">https://www.radhyg.ru/jour/article/view/401</self-uri><abstract><p>В статье рассмотрен подход к спектрометрии α-частиц с использованием твердотельных трековых детекторов типа CR-39 в энергетическом диапазоне 4-6 МэВ. Описаны этапы получения экспериментальной информации от облучения твердотельных трековых детекторов до его травления с последующим анализом отдельных треков. Представлены результаты измерений образцов, которые содержат изотопы плутония, а также зависимость минимально детектируемой активности от времени экспозиции и активности метки для одного из нуклидов.</p></abstract><trans-abstract xml:lang="en"><p>Alpha spectrometry approach using solid state nuclear track detectors  of CR-39 type is considered within the energy range 4-6 MeV. Experimental information obtaining stages are described from solid state nuclear track detectors  irradiation procedure to follow analysis of individual tracks. Results of plutonium isotopes contained samples and dependence of minimal detectible activity from exposure time and spike (tracer) activity for nuclide are presented.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>твердотельные трековые детекторы</kwd><kwd>пассивные детекторы</kwd><kwd>CR-39</kwd><kwd>обработка изображений треков</kwd><kwd>травление детекторов</kwd></kwd-group><kwd-group xml:lang="en"><kwd>Solid-state nuclear detecto</kwd><kwd>passive detectors</kwd><kwd>CR-39</kwd><kwd>processing images of tracks</kwd><kwd>irradiation procedure</kwd><kwd>MDA</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Нормы радиационной безопасности Украины (НРБУ - 97). Киев, 1997. 121 с.</mixed-citation><mixed-citation xml:lang="en">Нормы радиационной безопасности Украины (НРБУ - 97). Киев, 1997. 121 с.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Горн Л.С., Хазанов Б.И. Избирательные радиометры. М.: Атомиздат, 1975. 376 с.</mixed-citation><mixed-citation xml:lang="en">Горн Л.С., Хазанов Б.И. Избирательные радиометры. М.: Атомиздат, 1975. 376 с.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Горн Л.С., Хазанов Б.И. Современные приборы для измерения ионизирующих излучений. М.: Энергоатомиздат, 1989. 232 с.</mixed-citation><mixed-citation xml:lang="en">Горн Л.С., Хазанов Б.И. Современные приборы для измерения ионизирующих излучений. М.: Энергоатомиздат, 1989. 232 с.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Дементьев В.А. Измерение малых активностей радиоактивных препаратов. М.: Атомиздат, 1967. 140 с.</mixed-citation><mixed-citation xml:lang="en">Дементьев В.А. Измерение малых активностей радиоактивных препаратов. М.: Атомиздат, 1967. 140 с.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Брегадзе Ю.И., Степанов Э.К., Ярына В.П. Прикладная метрология ионизирующих излучений. М.: Энергоатомиздат, 1990. 264 с.</mixed-citation><mixed-citation xml:lang="en">Брегадзе Ю.И., Степанов Э.К., Ярына В.П. Прикладная метрология ионизирующих излучений. М.: Энергоатомиздат, 1990. 264 с.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Fews A.P., Fully automated image analysis of etched tracks in CR-39 // Nucl. Instr. Meth. Phys. Res. B, 1992. Vol. 71. P. 465.</mixed-citation><mixed-citation xml:lang="en">Fews A.P., Fully automated image analysis of etched tracks in CR-39 // Nucl. Instr. Meth. Phys. Res. B, 1992. Vol. 71. P. 465.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Gammage R., Espinosa G. Digital imaging system for track measurements // Radiat. Measur, 1997. Vol. 28. P. 835.</mixed-citation><mixed-citation xml:lang="en">Gammage R., Espinosa G. Digital imaging system for track measurements // Radiat. Measur, 1997. Vol. 28. P. 835.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
