<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">radhyd</journal-id><journal-title-group><journal-title xml:lang="ru">Радиационная гигиена</journal-title><trans-title-group xml:lang="en"><trans-title>Radiatsionnaya Gygiena = Radiation Hygiene</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1998-426X</issn><issn pub-type="epub">2409-9082</issn><publisher><publisher-name>NIIRG</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21514/1998-426X-2019-12-3-69-77</article-id><article-id custom-type="elpub" pub-id-type="custom">radhyd-643</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Научные статьи</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>Scientific articles</subject></subj-group></article-categories><title-group><article-title>Оценка доз медицинского облучения при рентгенографических стоматологических исследованиях</article-title><trans-title-group xml:lang="en"><trans-title>Dose assessment of medical exposure of radiographic dental studies</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Шацкий</surname><given-names>И. Г.</given-names></name><name name-style="western" xml:lang="en"><surname>Shatskiy</surname><given-names>I. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Шацкий Илья Геннадьевич – научный сотрудник лаборатории радиационной гигиены медицинских организаций</p><p>197101, Санкт-Петербург, ул. Мира, д. 8.</p></bio><bio xml:lang="en"><p>Ilya G. Shatskiy – Researcher, Medical protection laboratory</p><p>Mira str., 8, St. Petersburg, 197101.</p></bio><email xlink:type="simple">I.Shatskiy@niirg.ru</email><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Санкт-Петербургский научно-исследовательский институт радиационной гигиены имени профессора П.В.Рамзаева Федеральной службы по надзору в сфере защиты прав потребителей и благополучия человека</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Federal Service for Surveillance on Consumer Rights Protection and Human Well-Being</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2019</year></pub-date><pub-date pub-type="epub"><day>09</day><month>10</month><year>2019</year></pub-date><volume>12</volume><issue>3</issue><fpage>69</fpage><lpage>77</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Шацкий И.Г., 2019</copyright-statement><copyright-year>2019</copyright-year><copyright-holder xml:lang="ru">Шацкий И.Г.</copyright-holder><copyright-holder xml:lang="en">Shatskiy I.G.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.radhyg.ru/jour/article/view/643">https://www.radhyg.ru/jour/article/view/643</self-uri><abstract><p>Цель исследования заключается в оценке эффективных доз пациентов при выполнении дентальных исследований (внутриротовых прицельных снимков), сравнении полученных данных с литературными, а также со справочными значениями, приведенными в методических рекомендациях «Заполнение форм федерального государственного статистического наблюдения № 3-ДОЗ» и до сих пор нередко используемыми для заполнения формы вместо измеренных значений. В рамках данной работы в 2016–2018 гг. были обследованы 44 рентгено-стоматологических аппарата в 37 стоматологических медицинских организациях в г. Санкт-Петербурге и Ленинградской области. Были включены семь рентгенографических исследований: прицельные снимки трех групп зубов (резцы, премоляры и моляры) для верхней и нижней челюсти и рентгенография прикуса. Были собраны физико-технические и геометрические параметры для выбранных типов исследований стандартных пациентов: напряжения на рентгеновской трубке, общая фильтрация, радиационный выход, комбинация времени и тока экспозиции или экспозиция, область исследования, размеры поля облучения; фокусное расстояние. Далее были выполнены расчеты входной дозы в воздухе на базе значений радиационного выхода аппаратов. Затем на основании информации о параметрах проведения процедур и входной дозы были вычислены с использованием программы PCXMC эффективные дозы. Представлены полученные значения эффективных доз для всех аппаратов и исследований, включенных в данную работу. Для большинства аппаратов значения находятся в диапазоне от 0,5 до 10,7 мкЗв, что значительно меньше значений, используемых при заполнении формы 3-ДОЗ. Результаты оценки эффективной дозы достаточно однородны. Только на одном аппарате были зарегистрированы аномально высокие дозы, значительно превышающие не только значения доз на остальных аппаратах, но и значения из рекомендаций по заполнению формы 3-ДОЗ. Показаны распределения числа аппаратов по интервалам эффективной дозы. Медианы значений эффективной дозы для аппаратов с пленочными приемниками составили для резцов верхней челюсти – 3,2 мкЗв, премоляров верхней челюсти – 3,8 мкЗв, моляров верхней челюсти – 6,8 мкЗв, для резцов, премоляров и моляров нижней челюсти – 3,2; 3,4 и 5,8 мкЗв соответственно, а для рентгенографии прикуса – 6,7 мкЗв. Для аппаратов с цифровыми приемниками: 1 мкЗв, 1,2 мкЗв, 2,2 мкЗв – для верхней челюсти, 1 мкЗв, 1,3 мкЗв, 2 мкЗв – для нижней челюсти и 2,8 мкЗв – для прикуса соответственно. Обращает на себя внимание существенная ширина диапазонов без выбросов для исследований моляров обеих челюстей, что является поводом для возможного усиления оптимизационных мероприятий при проведении данных исследований. При сравнении с опубликованными данными установлено, что эффективные дозы в Санкт-Петербургских и областных стоматологических учреждениях ниже, чем значения, полученные при использовании стандартного круглого коллиматора и пленок средней и высокой чувствительности (класс D и F соответственно), а также ниже уровней доз в рекомендациях Европейской комиссии. Кроме того, результаты данного исследования существенно ниже значений, приведенных в методических рекомендациях «Заполнение форм федерального государственного статистического наблюдения № 3-ДОЗ» и до сих пор нередко используемых для заполнения формы вместо измеренных значений, что свидетельствует о завышении оценок доз пациентов при использовании справочных значений из руководства по форме 3-ДОЗ и необходимости использовать дозы пациентов, полученные на основании измерений и последующих расчетов. Однако эффективные дозы в Санкт-Петербурге и Ленинградской области выше, чем полученные при использовании квадратного коллиматора и пленок высокой чувствительности. Приведенные результаты позволяют говорить о необходимости и возможностях проведения оптимизации при рентгено-стоматологических исследованиях в Санкт-Петербурге и Ленинградской области. Анализ аналогичных исследований по другим рентгенодиагностическим техникам позволяет экстраполировать данное утверждение на остальные регионы России.</p></abstract><trans-abstract xml:lang="en"><p>The purpose of the study is to evaluate the effective doses of patients for the most common radiographic dental studies, comparing the obtained data with the literature and reference values given in the guidelines “Filling in the forms of the federal state statistical observation No. 3-DOZ” and are still often used for form filling instead of measured values. In the framework of this work in 2016-2018, 44 X-ray units were examined at 37 dental medical facilities in St. Petersburg and the Leningrad Region. Seven radiographic studies were included: radiographs of three groups of teeth (incisors, premolars, and molars) for the upper and lower jaw and bite radiography. Physical-technical and geometrical parameters were collected for selected types of the standard patient studies: X-ray tube voltages, total filtration, radiation output, combination of the time and the current of exposure or the exposure, area of the study, size of the irradiation field; the focal length. Further, the input (surface) dose was calculated from the radiation output of the device. Then, based on the initial information about the parameters of the procedures and the input dose, the absorbed doses and the effective dose were calculated using the PCXMC program. For most devices, the dose values are in the range of 0.5 to 10.7 µSv, which is significantly lower than the values used to fill in the 3-DOS form. The results of evaluating the effective dose for these devices are fairly homogeneous, but on one device, there were doses exceeding not only the values of doses on other devices, but also the values from the recommendations for 3-DOS for devices with digital receivers, as well as those approaching similar values for film devices. An almost linear dependence of the effective dose on the exposure time was established, while a similar dependence on the voltage on the X-ray tube was not found. The median value of the effective dose for the units with films detectors was 3.2 µSv for the maxillary incisors, 3.8 µSv for the maxillary premolars, 6.8 µSv for the maxillary molars, and for the mandibular incisors, premolars and molars – 3.2, 3.4 and 5.8 µSv, and for bitewing – 6.7 µSv. For the unit with digital detectors, effective doses were 1 µSv, 1,2 µSv, 2,2 µSv for maxilla, 1 µSv, 1,3 µSv, 2 µSv for mandibula and 2,8 µSv for bitewing. Attention is drawn to the substantial width of the ranges without emissions for the examination of premolars of the upper jaw, molars of both jaws and occlusion, which is the reason for the possible enhancement of optimization measures in these studies. When comparing with published data, it was found that the effective doses in St. Petersburg and the regional institutions are lower than the values obtained using standard round collimator and medium and high sensitivity films (class D and F, respectively), as well as lower dose levels in the European Commission Guidelines. In addition, the dose values deduced in this study are significantly lower than the values given in the guidelines “Filling in the forms of federal state statistical observation No. 3-DOZ” and which are still often used to fill in the form instead of the measured values. This indicates an overestimation of estimates of patient doses when using reference values from the 3-DOZ manual and the need to use individual patient doses, obtained on the basis of measurements. However, the effective doses in St. Petersburg and the Leningrad Region are higher than those obtained using a square collimator and high-sensitivity films. The above results suggest that it is necessary and possible to carry out optimization in X-ray dental studies in St. Petersburg and the Leningrad Region. Analysis of similar studies on other X-ray diagnostic techniques allows to extrapolate this statement to other regions of Russia.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>медицинское облучение</kwd><kwd>рентгенографический исследования</kwd><kwd>стоматологические исследования</kwd><kwd>пациенты</kwd><kwd>эффективная доза</kwd></kwd-group><kwd-group xml:lang="en"><kwd>medical exposure</kwd><kwd>radiographic examinations</kwd><kwd>dental examinations</kwd><kwd>patients</kwd><kwd>effective dose</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">United Nations Scientific Committee on the Effects of Atomic Radiation. Effects of Ionizing Radiation, UNSCEAR 2006 Report, Volume I, Annex A, NY, United Nations, 2008.</mixed-citation><mixed-citation xml:lang="en">United Nations Scientific Committee on the Effects of Atomic Radiation. Effects of Ionizing Radiation, UNSCEAR 2006 Report, Volume I, Annex A, NY, United Nations, 2008.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Tomohiro Okano Jaideep Sur. Radiation dose and protection in dentistry. Japanese Dental Science Review, Volume 46, Issue 2, August 2010, Pages 112-121.</mixed-citation><mixed-citation xml:lang="en">Tomohiro Okano Jaideep Sur. Radiation dose and protection in dentistry. Japanese Dental Science Review, Volume 46, Issue 2, August 2010, Pages 112-121.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">International Commission on Radiological Protection «Radiological Protection in Medicine», ICRP Publication 105, Ann ICRP 37 (6). Elsevier; 2007.</mixed-citation><mixed-citation xml:lang="en">International  Commission  on  Radiological  Protection «Radiological Protection in Medicine», ICRP Publication 105, Ann ICRP 37 (6). Elsevier; 2007.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Cristy M. Mathematical phantoms representing children of various ages for use in estimates of internal dose. Oak Ridge National Laboratory, ORNL/NUREG/TM-367 (1980).</mixed-citation><mixed-citation xml:lang="en">Cristy M. Mathematical phantoms representing children of various ages for use in estimates of internal dose. Oak Ridge National Laboratory, ORNL/NUREG/TM-367 (1980).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Tapiovaara M., Lakkisto M., Servomaa A. PCXMC: A PCbased Monte Carlo program for calculating patient doses in medical x-ray examinations. Report STUK-A139, 2nd Edition. Helsinki, Finnish Centre for Radiation and Nuclear Safety, 2008.</mixed-citation><mixed-citation xml:lang="en">Tapiovaara M., Lakkisto M., Servomaa A. PCXMC: A PCbased Monte Carlo program for calculating patient doses in medical x-ray examinations. Report STUK-A139, 2nd Edition. Helsinki, Finnish Centre for Radiation and Nuclear Safety, 2008.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">S.C. White, M.J. Pharoah. Oral radiology: principles and interpretation. (6th ed.), Mosby Elsevier, St. Louis (2009).</mixed-citation><mixed-citation xml:lang="en">S.C. White, M.J. Pharoah. Oral radiology: principles and interpretation. (6th ed.), Mosby Elsevier, St. Louis (2009).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">European Commission. Radiation Protection 136. European Guidelines on Radiation Protection in Dental Radiology. Luxembourg: Office for Official Publications of the European Сommunities, 2004.</mixed-citation><mixed-citation xml:lang="en">European Commission. Radiation Protection 136. European Guidelines on Radiation Protection in Dental Radiology. Luxembourg: Office for Official Publications of the European Сommunities, 2004.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">American Dental Association Council on Scientific Affairs: The use of dental radiographs. Update and recommendations. J Am Dent Assoc 2006;137:1304–12.</mixed-citation><mixed-citation xml:lang="en">American Dental Association Council on Scientific Affairs: The use of dental radiographs. Update and recommendations. J Am Dent Assoc 2006;137:1304–12.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">K. Syriopoulos, X.L. Velders, G.C.H. Sanderink, P.F. van der Stelt Sensitometric and clinical evaluation of a new F-speed dental X-ray film Dentomaxillofac Radiol, 30 (2001), pp. 40-44.</mixed-citation><mixed-citation xml:lang="en">K. Syriopoulos, X.L. Velders, G.C.H. Sanderink, P.F. van der Stelt Sensitometric and clinical evaluation of a new F-speed dental X-ray film Dentomaxillofac Radiol, 30 (2001), pp. 40-44.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">M. Alcaraz, C. Parra, Y. Martinez Beneyto, E. Velasco, M. Canteras Is it true that the radiation dose to which patients are exposed has decreased with modern radiographic films? Dentomaxillofac Radiol, 38 (2009), pp. 92-97.</mixed-citation><mixed-citation xml:lang="en">M. Alcaraz, C. Parra, Y. Martinez Beneyto, E. Velasco, M. Canteras Is it true that the radiation dose to which patients are exposed has decreased with modern radiographic films? Dentomaxillofac Radiol, 38 (2009), pp. 92-97.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">S.C. White, E.W. Heslop, L.G. Hollender, K.M. Mosier, A. Ruprecht, M.K. Shrout Parameters of radiologic care: an official report of the American Academy of oral and maxillofacial radiology Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 91 (2001), pp. 498-511.</mixed-citation><mixed-citation xml:lang="en">S.C. White, E.W. Heslop, L.G. Hollender, K.M. Mosier, A. Ruprecht, M.K. Shrout Parameters of radiologic care: an official report of the American Academy of oral and maxillofacial radiology Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 91 (2001), pp. 498-511.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">K. Horner, P.N. Hirschmann Dose reduction in dental radiography J Dent, 18 (1990), pp. 171-184.</mixed-citation><mixed-citation xml:lang="en">K. Horner, P.N. Hirschmann Dose reduction in dental radiography J Dent, 18 (1990), pp. 171-184.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">L.T. Kircos, L.L. Angin, L. Lortan Order of magnitude dose reduction in intraoral radiography J Am Dent Assoc, 114 (1987), pp. 344-347.</mixed-citation><mixed-citation xml:lang="en">L.T. Kircos, L.L. Angin, L. Lortan Order of magnitude dose reduction in intraoral radiography J Am Dent Assoc, 114 (1987), pp. 344-347.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">J.P. Freeman, J.W. Brand Radiation doses of commonly used dental radiographic surveys Oral Surg Oral Med Oral Pathol, 77 (1994), pp. 285-289.</mixed-citation><mixed-citation xml:lang="en">J.P. Freeman, J.W. Brand Radiation doses of commonly used dental radiographic surveys Oral Surg Oral Med Oral Pathol, 77 (1994), pp. 285-289.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">K. Horner Radiation protection in dental radiology Br J Radiol, 67 (1994), pp. 1041-1049.</mixed-citation><mixed-citation xml:lang="en">K. Horner Radiation protection in dental radiology Br J Radiol, 67 (1994), pp. 1041-1049.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
