ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS
https://doi.org/10.21514/1998-426X-2018-11-1-93-100
Abstract
Fluoroscopic examinations of the upper gastro-intestinal tract and, especially, barium meal examinations, are commonly performed in a majority of hospitals. These examinations are associated both with substantial individual patient doses and contribution to the collective dose from medical exposure. Effective dose estimation for this type of examinations is complicated due to: 1) the necessity to simulate the moving X-ray irradiation field; 2) differences in study structure for the individual patients; 3) subjectivity of the operators; and 4) differences in the X-ray equipment. The aim of the current study was to estimate conversion coefficients from dose-area product to effective dose for barium meal examinations for the over couch and under couch exposure conditions. The study was based on data collected in the X-ray unit of the surgical department of the St-Petersburg Mariinsky hospital. A model of patient exposure during barium meal examination was developed based on the collected data on fluoroscopy protocols and adult patient irradiation geometry. Conversion coefficients were calculated using PCXMC 2.0 software. Complete examinations were converted into a set of typical fluoroscopy phases and X-ray images, specified by the examined anatomical region and the projection of patient exposure. Conversion coefficients from dose-area product to effective dose were calculated for each phase of the examination and for the complete examination. The resulting values of the conversion coefficients are comparable with published data. Variations in the absolute values of the conversion coefficients can be explained by differences in clinical protocols, models for the estimation of the effective dose and parameters of barium meal examinations. The proposed approach for estimation of effective dose considers such important features of fluoroscopic examinations as: 1) non-uniform structure of examination, 2) significant movement of the X-ray tube within a single fluoroscopic phase, and 3) the variety of exposure geometries within complete examination.
About the Authors
A. V. VodovatovRussian Federation
Aleksandr V. Vodovatov – PhD, the acting head of the Protection Laboratory, SPRIRH after Professor P.V. Ramzaev; Federal Service for Surveillance on Consumer Rights Protection and Human Well-Being.
Mira Str., 8, Saint-Petersburg, 197101
V. Yu. Golikov
Russian Federation
Vladislav Yu. Golikov – leading scientist, the Protection Laboratory
I. G. Kamyshanskaya
Russian Federation
Irina G. Kamyshanskaya – MD, PhD, associate Professor SPSU Department of Oncology, head of X-ray Department, St-Petersburg UMH
K. V. Zinkevich
Russian Federation
Kseniya V. Zinkevich – resident.
St-Petersburg
Ch. Bernhardsson
Sweden
Christian Bernhardsson – PhD, associated professor MRPDepartment of Translational Medicine LU, SUH.
Malmö
References
1. Barkovsky A.N. [et. al.]. Doses from ionizing radiation to the public of Russian Federation in 2015. Information bulletin. St-Petersburg, 2016, 73 p. (in Russian).
2. European Commission. Medical Radiation Exposure of the European Population. Radiation Protection 180 pt. 1. European Commission (2014).
3. Hart D., Jones D.G. and Wall B.F. Estimation of effective dose in diagnostic radiology from entrance dose and dosearea product measurements. NRPB Report R-262 (London: HMSO) (1994).
4. Wall B.F., Haylock R., Jansen J.T.M., Hillier M.C., Hart D. and Shrimpton P.C. Radiation Risks from Medical X-ray Examinations as a Function of the Age and Sex of the Patient. HPA-CRCE-028. Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency (2011). Available on: https://pdfs.semanticscholar.org/d90f/22c2c119c618c6822eb094087464e5ca3c4b.pdf (Accessed 10.02.2018).
5. Hart D. and Wall B.F. Estimation of effective dose from dose-area product measurements for barium meals and barium enemas. Br. J. Radiol. 67, 485-489 (1994).
6. Student radiographer. Guide to learning radiography. Fluoroscopy equipment. Available on: https://studentradiographer.com/?p=873 (Accessed 10.02.2018).
7. Tapiovaara M., Siiskonen T., 2008. PCXMC: A Monte Carlo program for calculating patient doses in medical x-ray examinations. 2nd Ed. STUK, Finalnd.
8. ICRP – International Commission on Radiological Protection, 2007. Recommendations of the International Commission on Radiological Protection. ICRP Publication 103. Ann. ICRP., Vol. 37, No. 2–4.
9. Bonilha H.S., Wilmskoetter J., Tipnis S.V., Martin-Harris B. and Huda W. Effective dose per unit kerma-area product conversion factors in adults undergoing modified barium swallow studies. Rad. Prot. Dos. 1-9 (2017). doi:10.1093/rpd/ncx006.
10. Delichas M.G., Hatziioannou K., Papanastassiou E., Albanopoulou P., Chatzi E., Sioundas A. and Psarrakos K. Radiation doses to patients undergoing barium meal and barium enema examinations. Rad. Prot. Dos. 109(1-3), 243247 (2004).
11. Ciraj O., Markovic S., Kosutic D. Patient doses for barium meal examinations in Serbia and Montenegro and potentials for dose reduction through changes in equipment settings. Rad. Prot. Dos. 114(1-3), 158-163 (2005).
12. Gyekey P.K., Schandorf C., Boadu M., Yeboah J., Amoako J.K. Patient dose assessment due to fluoroscopic exposure for some selected fluoroscopic procedures in Ghana. Rad. Prot. Dos. 136(3), 203-208 (2009).
Review
For citations:
Vodovatov A.V., Golikov V.Yu., Kamyshanskaya I.G., Zinkevich K.V., Bernhardsson Ch. ESTIMATION OF THE CONVERSION COEFFICIENTS FROM DOSE-AREA PRODUCT TO EFFECTIVE DOSE FOR BARIUM MEAL EXAMINATIONS FOR ADULT PATIENTS. Radiatsionnaya Gygiena = Radiation Hygiene. 2018;11(1):93-100. (In Russ.) https://doi.org/10.21514/1998-426X-2018-11-1-93-100