Automated calculation of radiation doses and radiation risks during computed tomography: advantages and limitations of the programs used
https://doi.org/10.21514/1998-426X-2026-19-3-84-96
Abstract
The increasing number of computed tomography examinations is associated with growing collective medical radiation exposure and the number of unjustified imaging referrals, highlighting the importance of rapid automated tools for assessing patient radiation risks. Purpose is to analyze the capabilities of application programs for automated calculation of radiation doses and radiation risk during computed tomography. Materials and Methods: A comparative analysis of seven software programs designed to calculate the effective radiation dose during computed tomography was conducted. For each program, the input and output parameters, dose calculation algorithms, coefficients used, and ease of use were analyzed. A comparison of the calculated doses and radiation risk levels for computed tomography of the head, thorax and abdomen was performed. Results and Discusiion: Analyzed programs are grouped into three clusters: 1) determining only the effective dose; 2) calculating organ doses and the effective dose; 3) calculating the effective dose and radiation risks. Programs in cluster 1 estimate only the effective dose using coefficients for the selected anatomical region. Programs in cluster 2 provide a more accurate estimate of the effective dose, as the calculation is based on organ doses and takes into account scanning parameters. Programs in cluster 3 provide the most accurate results; they also calculate radiation risk levels and generate reports on series. The spread of effective dose values between different programs for the same anatomical regions is up to 30–40%, due to the use of different methods and standard coefficients. All of the programs reviewed take into account the doses accumulated during various medical diagnostic procedures, and not all of them provide recommendations on the use of radiation diagnostic methods for a specific patient. Conclusion: The use of automated calculation software facilitates the assessment of radiation doses during computed tomography scans and patient radiation risk levels. Existing solutions are limited by the lack of integration with radiation registries and the inability to account for the total radiation doses of patients employed at radiation facilities for diagnostic purposes and in professional settings, which remains a pressing issue in the field of radiation hygiene and radiation safety.
About the Author
E. I. MatkevichRussian Federation
Elena I. Matkevich – Candidate of Medical Sciences, Radiologist, Head of the Department of MRI Diagnostics
23, Marshal Novikov Str., Moscow, 123098
References
1. Kanal KM, Butler PF, Sengupta D, Bhargavan-Chatfield M, Coombs LP, Morin RL. U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations. Radiology. 2017;284(1): 120-133. DOI: 10.1148/radiol.2017161911.
2. Lee KL, Beveridge T, Sanagou M, Thomas P. Updated Australian diagnostic reference levels for adult CT. Journal of Medical Radiation Sciences. 2020;67(1): 5–15. DOI: 10.1002/jmrs.372.
3. Shrimpton PC, Hillier MC, Meeson S, Golding SJ. Doses from Computed Tomography (CT) Examinations in the UK-2011 Review. Public Health England, London (UK); 2014. P. 129.
4. Kosterev VV, Tsovyanov AG, Sivenkov AG, Zhuravleva VE. Population radiation dose in 2020. Nuclear Physics and Engineering. 2022;13(6): 594–600. DOI: 10.56304/S2079562922030277 (In Russian). Medical software and more. Available from: https://medsoftpro.ru/kalkulyatory/effektivnaya-doza.html [Accessed 07.03.2026].
5. RUSTORE a calculator for your smartphone. Available from: https://www.rustore.ru/catalog/app/ru.medsoftpro.ctdi [Accessed 07.02.2026].
6. Vasiliev VA, Lantukh ZA, Druzhinina YuV, Naumov MI, Ryzhov SA, et al. Computer program «Calculator of effective doses to patients during computed tomography» No. 2024617710, registration date 04.04.2024; Calculator for calculating the effective dose for CT of the Diagnostics and Telemedicine Center. Available from: https://3doz.telemedai.ru/calculator /ct/?age=%3E17&diameter=32-sm&body-part=grudnaya [Accessed 07.03.2026] (In Russian).
7. VirtualDoseCT. Available from: http://www.virtualphantoms. com/our-products/virtualdose/ [Accessed 07.03.2026].
8. Repin LV, Biblin AM. On the development of a mobile application for assessing the radiation risk associated with medical X-ray and radiological studies. Radiatsionnaya Gygiena = Radiation Hygiene. 2025;18(3): 112-119. DOI: 10.21514/1998-426X-2025-18-3-112-119. (In Russian).
9. X-RAY RISK Calculator. Available from: https://www.xrayrisk. com/about.php [Accessed 07.03.2026].
10. Matkevich EI, Bashkov AN, Parinov OV, Samoilov AS. Computer and magnetic resonance imaging in diagnostic practice. The possibility of optimizing studies in order to reduce radiation exposure. Meditsinskaya radiologiya i radiatsionnaya bezopasnost = Medical Radiology and Radiation Safety. 2025;70(1): 30-38. DOI 10.33266/10246177-2025-70-1-30-38. (In Russian).
11. Bahadori A, Miglioretti D, Kruger R, Flynn M, Weinmann Sh, Smith-Bindmanet R, et al. Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations. American journal of roentgenology. 2015;205(4): 827-833. DOI: 10.2214/AJR.14.14135.
12. ICRP Publication 152: Radiation Detriment Calculation Methodology. Annals of the ICRP. 2022;51(3): 9-103. DOI: 10.1177/01466453221080101.
13. National Research Council. Health risks from exposure to low levels of ionizing radiation. BEIR VII. Washington, DC: National Academies Press; 2006.
14. The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication
15. Annals of the ICRP. 2007;37(2-4): 1-332. DOI: 10.1016/j.icrp.2007.10.003.
16. The 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Annals of the ICRP. 1991: 202.
17. Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M. Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology. 2008;248(1): 254-263. DOI: 10.1148/radiol.2481071451.
18. Huda W, Ogden KM, Khorasani MR. Converting dose-length product to effective dose at CT. Radiology. 2008;248(3): 9951003. DOI: 10.1148/radiol.2483071964.
19. Chipiga LA. A comparison of computational methods for estimation of effective and organ doses to the patients from CT examination. Radiatsionnaya gygiena = Radiation Hygiene. 2017;10(1): 56-64. DOI: 10.21514/1998-426Х2017-10-1-56-64 (In Russian).
20. Rehani MM, Xu XG. Dose, dose, dose, but where is the patient dose? Radiation Protection Dosimetry. 2024;200(10): 945955. DOI: 10.1093/rpd/ncae137.
21. CT-Expo. Available from: http://www.sascrad.com/services/ software-development/ [Accessed 07.03.2026].
22. ImPACT CT Patient Dosimetry Calculator (version 1.0.4 27/05/2011). Available from: https://www.ukhsaprotectionservices.org.uk/mdg/patientdosimetry/patientdos eestimationtool [Accessed 07.03.2026].
23. National Cancer Institute dosimetry system for Computed Tomography (NCICT) Computer Program. Available from: https://dceg.cancer.gov/tools/radiation-dosimetrytools/computed-tomography [Accessed 07.03.2026].
Review
For citations:
Matkevich E.I. Automated calculation of radiation doses and radiation risks during computed tomography: advantages and limitations of the programs used. Radiatsionnaya Gygiena = Radiation Hygiene. 2026;19(3):84-96. (In Russ.) https://doi.org/10.21514/1998-426X-2026-19-3-84-96
JATS XML