Preview

Radiatsionnaya Gygiena = Radiation Hygiene

Advanced search

OPTIMIZATION OF RADIATION PROTECTION BY ELIMINATING WEEDS OUT RASTER DIGITAL RADIOGRAPHY OF THE CHEST

Abstract

An experimental study of the possibility of eliminating the raster digital radiography. On stationary digital x-ray machine produced 117 x-ray images of the test object and x-rays of the chest cavity with the grid
and without him several patients-volunteers. Proven ability to eliminate grid digital radiography by digital processing of images, made without the grid that reduces dose radiation exposure of the patient more than in 3 times. «Virtual» grids enough improve the diagnostic quality of the photo to eliminate the pathology.

About the Authors

I. G. Kamyshanskaja
Saint-Petersburg State University, The Russian Government, Saint-Petersburg; City Mariinskaya hospital, The health Committee of Saint-Petersburg, Saint-Petersburg
Russian Federation


V. M. Cheremisin
Saint-Petersburg State University, The Russian Government, Saint-Petersburg; City Mariinskaya hospital, The health Committee of Saint-Petersburg, Saint-Petersburg
Russian Federation


N. V. Perepelicina
Saint-Petersburg State University, The Russian Government, Saint-Petersburg
Russian Federation


References

1. Mazurov, A.I. Bor’ba s rassejannym izlucheniem v cifrovyh rentgenovskih apparatah / A.I. Mazurova // Uvidet’ nevidimoe. – Sbornik nauch. trudov. – Vypusk 2. – SPb.: OOO “SPb SRP “Pavel” VOG”, 2012. – S. 85–97.

2. Bontrager, K.L. Rukovodstvo po rentgenografii s rentgenoanatomicheskim atlasom ukladok / K.L. Bontrager. – M.: Intelmedtehnika, 2005.

3. Blinov, N.N. Teoreticheskoe obosnovanie, issledovanie i razrabotka metodov i sredstv minimizacii luchevoj nagruzki v sovremennyh rentgenodiagnosticheskih apparatah : dis. ... d-ra tehn. nauk: 05.11.10. / N.N. Blinov. – M., 2004. – 289 s.

4. Mazurov, A.I. Issledovanija po optimizacii rastrov dlja cifrovyh rentgenovskih apparatov / A.I. Mazurov [i dr.]. – SPb.: ZAO «NIIPK «Jelektron», 2008. – 18 s.

5. Mazurov, A.I. Optimizacija tehnicheskih sredstv rentgenologicheskoj sluzhby lechebno-profilakticheskih uchrezhdenij / A.I. Mazurov, G.N. Pahar’kov // Vestnik Severo- Zapadnogo regional’nogo otdelenija Akademii medikotehnicheskih nauk. – 2003. – № 7. – S. 102–107.

6. Kamyshanskaja, I.G. Snizhenie luchevyh nagruzok pri issledovanijah na cifrovyh rentgenovsvkih apparatah / I.G. Kamyshanskaja, A.I. Mazurov // Biotehnosfera. – 2010. – № 4 (10) – S. 33–37.

7. Mazurov, A.I. Jevoljucija priemnikov rentgenovskih izobrazhenij / A.I. Mazurov // Medicinskaja tehnika. – 2004. – № 5. – S. 34–37.

8. Kanter, B.M. Issledovanie i razrabotka metodov i sredstv rentgenovskoj cifrovoj medicinskoj diagnostiki : avtoref. diss. …doktora teh. nauk / B.M. Kanter. – M., 2000.

9. Jelinson, M.B. Puti snizhenija luchevyh nagruzok v rentgenodiagnostike / M.B. Jelinson, A.I. Mazurov // Materialy Nevskogo radiologicheskogo foruma «Nauka-klinike», Sankt- Peterburg, 9–12 aprelja 2005 g. – SPb., 2005. – S.404.

10. Zajavka SShA US 2010046822 na izobretenie «Virtual grid imaging method and system for eliminating scattered radiation effect» opublikovana 25.02.2010.


Review

For citations:


Kamyshanskaja I.G., Cheremisin V.M., Perepelicina N.V. OPTIMIZATION OF RADIATION PROTECTION BY ELIMINATING WEEDS OUT RASTER DIGITAL RADIOGRAPHY OF THE CHEST. Radiatsionnaya Gygiena = Radiation Hygiene. 2015;8(2):19-24. (In Russ.)

Views: 893


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-426X (Print)
ISSN 2409-9082 (Online)