EXPERIMENTAL STUDY OF INDIVIDUAL THERMOLUMINESCENT DOSEMETERS PERFORMANCES FOR MEASURING THE DOSE EQUIVALENTS IN SKIN AND EYE LENS

Abstract

The article gives a comparative analysis of existing and newly developed thermoluminescent detectors DTG-4, TTLD-580, TLD-1011(TM) and DTVS-01 and dosemeters MKD-A and MKD-B for the purposes of individual dosimetric control of skin and eye lens exposure to radiation. The dependence of sensitivity of different thermoluminescent dosemeters, designed for dose equivalents measurements in skin and eye lens on the type (photons and ȕ-particles) and energy of radiation was determined experimentally. There are conclusions about the limits of applicability of existing detectors and dosemeters under different radiation exposure conditions. The article evaluates the possibility of different dosimeter use for specific radiation exposure conditions.

About the Author

E. N. Sheleenkova
Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev
Russian Federation


References

1. Radiation safety standard (NRB-99/2009): Sanitary rules and norms (SanPiN 2.6.1.2523-09): appr. and put into effect on 07.07.09, – M. : Federal center of hygiene and epidemiology, 2009. – 100 p.

2. Gimatoda T.I. Individual dosimeters for measurement of equivalent dose in the skin of the fingers, face and eye lens for chronic and emergency exposure/ Gimadova T. I., Shax A. I.// Equipment news of radiation measurements. – 2001. No. 3. – p. 21-27

3. Assessment of Occupational Exposure Due to Intakes of Radionuclides. Safety guide – Vienna: IAEA, 1999. № RS-G1.2. – p. 87.

4. Occupational Radiation Protection. Safety guide. – Vienna: IAEA, 1999.№ RS-G-1.1. – S. 78.

5. Control equivalent doses of photon and beta radiation in skin and eye lens. HOWTO (MU 2.6.1.56-2002). – M.: Russian Ministry of Health, 2002.

6. ISO 4037-1: 2006, X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy -Part 1: Radiation characteristics and production methods.

7. Agrinenko S. D., "Development of complex monitoring on the base of detectors LiF: Mg, Cu, P for the handling of RAO" dissertation VAK 05.17.02, candidate of Technical Sciences.

8. ISO 12794:2000, Nuclear energy – Radiation protection – Individual thermoluminescence dosemeters for extremities and eyes


Review

For citations:


Sheleenkova E.N. EXPERIMENTAL STUDY OF INDIVIDUAL THERMOLUMINESCENT DOSEMETERS PERFORMANCES FOR MEASURING THE DOSE EQUIVALENTS IN SKIN AND EYE LENS. Radiatsionnaya Gygiena = Radiation Hygiene. 2014;7(4):143-156.

Views: 861


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1998-426X (Print)
ISSN 2409-9082 (Online)